Request PDF / Print Copy
Documentation Library

ScintIQ Custom Scintillation Detectors

Data sheets, readout electronics, application briefs, configurators, and technical notes for the Berkeley Nucleonics ScintIQ™ line of custom scintillation detector assemblies.

Material Data Sheets

Specifications, emission properties, and performance data for each scintillator crystal offered in the ScintIQ™ line.

NaI(Tl)

NaI(Tl) — Sodium Iodide

High light yield workhorse crystal; the standard for general gamma spectroscopy and isotope identification.

Open →
Data Sheet

CsI(Tl) — Cesium Iodide

Rugged, slightly hygroscopic crystal with high light yield and excellent linearity; well-suited to portable systems.

Open →
Data Sheet

LaBr3(Ce) — Lanthanum Bromide

Outstanding energy resolution (2.6% at 662 keV) with fast decay; favored for high-resolution field spectroscopy.

Open →
CeBr3

CeBr3 — Cerium Bromide

Ultra-fast decay, low intrinsic background, and sub-3% resolution; a strong alternative to LaBr3 where background counts matter.

Open →
Data Sheet

LBC — Lanthanum Bromo-Chloride

Elpasolite-family crystal offering high resolution with reduced intrinsic activity compared to pure LaBr3.

Open →
Data Sheet

BaF2 — Barium Fluoride

Fastest known scintillator (sub-1 ns component); used in coincidence timing and time-of-flight measurements.

Open →
SrI2(Eu)

SrI2(Eu) — Strontium Iodide

Exceptional energy resolution near 2.4% at 662 keV with very high light yield; emerging standard for premium field systems.

Open →
Data Sheet

CLLBC — Dual-Mode Elpasolite

Simultaneous gamma and neutron detection in one crystal via pulse-shape discrimination; no separate He-3 tube required.

Open →
Data Sheet

CLYC:Ce — Dual-Mode Elpasolite

Strong neutron-gamma discrimination with good gamma resolution; widely used in dual-particle field instruments.

Open →
YAP:Ce

YAP:Ce — Yttrium Aluminum Perovskite

Rugged, non-hygroscopic oxide crystal with fast decay; suited to X-ray detection and high-temperature environments.

Open →
Data Sheet

YAG:Ce — Yttrium Aluminum Garnet

Dense oxide scintillator with excellent mechanical strength; non-hygroscopic and stable in demanding conditions.

Open →
GAGG:Ce

GAGG:Ce — Gadolinium Aluminum Gallium Garnet

High density, high light yield, non-hygroscopic; one of the brightest oxide crystals, favored for SiPM-coupled assemblies.

Open →
Data Sheet

LYSO — Lutetium Yttrium Oxyorthosilicate

High density and very fast decay make LYSO the choice for PET imaging and time-of-flight coincidence systems.

Open →
Data Sheet

BGO — Bismuth Germanate

Highest effective-Z of the standard crystals; no intrinsic radioactivity, non-hygroscopic, proven in PET and calorimetry.

Open →
Data Sheet

PbWO4 — Lead Tungstate

Very fast, radiation-hard, high-density crystal with low light yield; the calorimeter material for high-energy physics.

Open →
Data Sheet

6Li Glass — Lithium-6 Loaded Glass

Cerium-activated lithium-6 glass for direct thermal-neutron detection; non-hygroscopic and rugged for field probes.

Open →

Readout & Electronics Data Sheets

SiPM readout assemblies, multi-channel analyzers, digitizers, and complete detector systems from Berkeley Nucleonics.

Data Sheet

ScintIQ SiPM Readout Module

Universal SiPM front-end and bias supply for coupling any ScintIQ crystal to a digital MCA or digitizer.

Open →
Data Sheet

NaI(Tl) 2×2 SiPM Detector Assembly

Turnkey 2-inch x 2-inch NaI(Tl) detector with integrated SiPM array and signal conditioning; drop-in field unit.

Open →
Data Sheet

SiPM Alpha/Beta Detector

Thin-crystal SiPM assembly optimized for low-energy alpha and beta counting with pulse-shape separation.

Open →
TOPAZ-HR MCA

TOPAZ-HR High-Resolution MCA

16k-channel multi-channel analyzer with shaping amplifier, stabilization, and USB/Ethernet readout for lab spectroscopy.

Open →
TOPAZ-Pico MCA

TOPAZ-Pico Compact MCA

Palm-sized multi-channel analyzer for field deployments; battery-powered with Bluetooth streaming to mobile apps.

Open →
bMCA Ethernet

bMCA Ethernet Multi-Channel Analyzer

Network-connected MCA for remote and distributed monitoring; 4096 channels, PoE-capable, SNMP-ready.

Open →
bMCA USB

bMCA USB Multi-Channel Analyzer

Compact USB MCA with on-board HV supply; plug-and-play with any PMT or SiPM detector.

Open →
bPAD Digitizer

bPAD Pulse-Analysis Digitizer

High-speed waveform digitizer for pulse-shape discrimination; supports dual-mode crystals such as CLLBC and CLYC.

Open →
Data Sheet

bGamma Gamma Spectrometry Software

Acquisition and analysis software for ScintIQ MCAs: live spectra, energy calibration, ROI tools, and isotope library matching.

Open →
Data Sheet

V102AR406/3.5M-X6 Detector Assembly

Integrated PMT-coupled crystal detector assembly with voltage divider, ready to pair with a ScintIQ MCA or HV supply.

Open →

Configurators & Selection Tools

Interactive tools to compare materials, narrow down detector options, and generate a configuration for a quote.

Application Briefs

Short application notes covering how ScintIQ detectors are deployed across key markets and use cases.

Technical Notes & Reference

Background reading on scintillation physics, detector selection, and measurement technique.

Preliminary Berkeley Nucleonics ScintIQ™ documentation. Specifications are subject to verification against the published data sheets. Contact info@berkeleynucleonics.com or call 800-234-7858 with questions.